電(dian)器產品如(ru)何測(ce)試(shi)接(jie)地電(dian)阻
安規(gui)測試儀(yi)日(ri)常使用注意(yi)事(shi)...
測頭校正的原理
關于耐壓測試儀的檢(jian)查(cha)
青島合眾電子有(you)限公(gong)司
聯系人:李經理
手機:13335072661
QQ:531601677
郵箱:qdhzlyc@163.com
傳真:0532-80969901
網址(zhi):aaaaahx.cn
地址:青島市(shi)城(cheng)陽區(qu)書云東路(lu)57號(hao)盛文研發中心1號(hao)樓(lou)
什么是剩(sheng)余電流?
剩余(yu)電(dian)(dian)流(liu)(liu),是指低壓配電(dian)(dian)線(xian)(xian)路中(zhong)各相(xiang)(含中(zhong)性線(xian)(xian))電(dian)(dian)流(liu)(liu)矢量和不為零(ling)的電(dian)(dian)流(liu)(liu)。通俗來講,當用電(dian)(dian)側發(fa)生了事故,電(dian)(dian)流(liu)(liu)從帶電(dian)(dian)體通過(guo)人體流(liu)(liu)到(dao)大地,使主電(dian)(dian)路進出線(xian)(xian)中(zhong)的電(dian)(dian)流(liu)(liu)大小不相(xiang)等(deng),此時電(dian)(dian)流(liu)(liu)的瞬時矢量合成有效值(zhi)稱為剩余(yu)電(dian)(dian)流(liu)(liu),俗稱漏電(dian)(dian)。
所以通過監測剩余電流發生(sheng)的變化,就可以得知帶電導體對(dui)地絕緣是否(fou)被破(po)壞(huai),從而(er)啟動(dong)保護裝置(zhi)跳(tiao)閘,從而(er)來(lai)防(fang)止(zhi)發生(sheng)觸(chu)電及接地電弧引發的火災。
什(shen)么(me)是RCD?
RCD(Residual Current Device,剩余(yu)電流裝置,或者(zhe)也叫剩余(yu)電流動作(zuo)保護(hu)器(qi)(qi),俗稱“漏保”),是指在正常工作(zuo)條件下(xia),接通負載(zai)和斷開電流;而當電路的(de)剩余(yu)電流在規(gui)定的(de)條件下(xia)達到(dao)其(qi)規(gui)定值時,引起觸頭動作(zuo)而斷開主電路的(de)一(yi)種保護(hu)器(qi)(qi)。其(qi)作(zuo)用(yong)是防漏電引起的(de)火(huo)災和設(she)備(bei)燒毀(hui)事故。
RCD剩余電流安規測(ce)試儀檢(jian)測(ce)方法:
1.RCD 脫扣應不遲于(yu)達到其額定故(gu)障電流(liu)值時
2.不(bu)會超過各個系統(tong)所同意的持續允許的接觸電壓值UL
安(an)規(gui)測試儀通(tong)過以下(xia)方法實現(xian):
1.接觸電壓測(ce)量,全(quan)波測(ce)量和IΔN 外(wai)推的(de)10 次測(ce)量
2.通過IΔN 驗證在400 ms 或200 ms 內脫扣(測量到1000ms)
通過上升(sheng)剩余電流來驗(yan)證脫扣:
1.該(gai)值(zhi)必須介于IΔN 的50%至100%之(zhi)間(通常約為(wei)70%)。
2.使(shi)用此測(ce)試(shi)儀器(qi)不會(hui)過早脫扣,因為測(ce)試(shi)會(hui)以30%的剩(sheng)余電(dian)流(liu)(liu)開始(如果系統內(nei)沒(mei)有偏置電(dian)流(liu)(liu))。
關鍵詞:安規測試儀;安規(gui)綜合測試(shi)儀;電(dian)器安全性能綜合測試(shi)儀
Service project
聯(lian)系人:李經理
手機:13335072661
QQ:531601677
傳(chuan)真:0532-80969901
地址:青島市(shi)城陽區書云東路(lu)57號(hao)盛文研發中心(xin)1號(hao)樓
手機掃碼查看
什么是剩余電流?
剩余(yu)電(dian)(dian)流(liu),是指低壓配電(dian)(dian)線(xian)(xian)路中(zhong)各相(含中(zhong)性線(xian)(xian))電(dian)(dian)流(liu)矢(shi)量(liang)和不為(wei)零的電(dian)(dian)流(liu)。通俗來(lai)講(jiang),當用電(dian)(dian)側(ce)發生(sheng)了事故,電(dian)(dian)流(liu)從帶電(dian)(dian)體通過人體流(liu)到(dao)大(da)地,使主電(dian)(dian)路進(jin)出線(xian)(xian)中(zhong)的電(dian)(dian)流(liu)大(da)小不相等,此(ci)時電(dian)(dian)流(liu)的瞬時矢(shi)量(liang)合成有效值稱為(wei)剩余(yu)電(dian)(dian)流(liu),俗稱漏電(dian)(dian)。
所以(yi)通過(guo)監測剩余電(dian)流發生的變化,就可以(yi)得(de)知帶電(dian)導體對地絕緣是否被破壞,從而啟(qi)動保護裝置跳閘,從而來防(fang)止發生觸電(dian)及接地電(dian)弧引發的火災。
什么是RCD?
RCD(Residual Current Device,剩(sheng)余(yu)電流裝置,或者也叫剩(sheng)余(yu)電流動作(zuo)保(bao)(bao)護器,俗稱“漏(lou)保(bao)(bao)”),是(shi)指在(zai)正常工作(zuo)條(tiao)件(jian)(jian)下(xia),接(jie)通(tong)負載(zai)和(he)斷(duan)開電流;而(er)當電路(lu)的剩(sheng)余(yu)電流在(zai)規(gui)定的條(tiao)件(jian)(jian)下(xia)達(da)到其(qi)規(gui)定值(zhi)時,引(yin)起(qi)(qi)觸頭(tou)動作(zuo)而(er)斷(duan)開主(zhu)電路(lu)的一種保(bao)(bao)護器。其(qi)作(zuo)用是(shi)防漏(lou)電引(yin)起(qi)(qi)的火災和(he)設備燒毀事故。
RCD剩余(yu)電流安規測(ce)試儀檢(jian)測(ce)方(fang)法:
1.RCD 脫(tuo)扣應(ying)不遲于達到(dao)其(qi)額(e)定故障電流值時
2.不會(hui)超過各個系統(tong)所同意的持續允許的接觸(chu)電壓值UL
安規測試儀通過以下方法實(shi)現(xian):
1.接觸電壓測(ce)量,全波測(ce)量和(he)IΔN 外推的10 次(ci)測(ce)量
2.通過(guo)IΔN 驗(yan)證在400 ms 或200 ms 內脫扣(測量到1000ms)
通過上升剩余電(dian)流來(lai)驗證脫扣:
1.該值(zhi)必須介于(yu)IΔN 的(de)50%至(zhi)100%之間(通常(chang)約為70%)。
2.使(shi)用此測試儀器不(bu)會(hui)過早脫扣,因為測試會(hui)以30%的剩余電(dian)流開始(如果系(xi)統內沒有偏置電(dian)流)。
關鍵詞:安規測試儀;安(an)規綜合(he)測試(shi)儀;電(dian)器安(an)全性能綜合(he)測試(shi)儀